Specifications for: MM-EN600GU: Minuteman Enspire G Series UPS 600VA 330W |
SYSTEM SPECIFICATIONS |
Model Number |
EN450G |
EN600GU |
EN750G |
Topology |
Standby, Simulated Sine Wave |
Maximum Power Capacity |
450VA
250W |
600VA
330W |
750VA
450W |
INPUT |
Number of Phase |
Single (1Ø 2W +G) |
Nominal Voltage |
120VAC |
Acceptable Input Voltage |
0 - 150VAC |
Voltage Range |
95 - 140VAC |
Frequency Limits |
60 Hz, ±6Hz |
Low Voltage Transfer Point |
95V resets to Utility Power at 99V or higher |
High Voltage Transfer Point |
140V resets to Utility Power at 136V or lower |
Input Protection |
Resettable Circuit Breaker |
OUTPUT NON-BATTERY OPERATION |
Voltage Range |
95 - 140VAC |
Voltage Regulation |
120VAC: -20.8% - +16.7% |
Frequency Range |
60Hz: 54 - 66Hz |
Efficiency (Line Mode) |
>98% (Full Load) |
OUTPUT BATTERY OPERATION |
Waveform Type |
Simulated Sine Wave |
Nominal Voltage |
120VAC |
Voltage Regulation |
Nominal ±5% (until Low Battery Warning) |
Frequency |
60Hz, ±0.5Hz (unless synchronized to utility) |
Transfer Time |
6 ms Typical |
Overload Capacity |
AC Mode: 105% for 1-minute then shutdown,
115% Shutdown Immediately
DC Mode: 105% for 20-seconds then shutdown,
115% Shutdown Immediately |
Protection |
Over-Current, Short-Circuit Protected, Latching Shutdown |
REGULATORY COMPLIANCE |
Safety and Approvals |
cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3:2014/R:2017-10), FCC Class B, CE certified, RoHS2 (EU Directive 2011/65/EU & 2015/863/EU) |
BATTERY SYSTEM |
Battery Type |
Sealed, Non-Spillable, Maintenance Free, Value Regulated, Lead Acid |
Typical Recharge Time |
8-hours to 90% capacity from a full load discharge |
Typical Battery Life |
3 to 5 years. Environmental factors do affect battery life. High temperatures, poor utility power, and frequent, short duration discharges have a negative impact on battery life. |
Battery Module Part # |
BM0094 |
BM0095 |
Runtime: Full Load (minutes) |
2 |
3 |
Runtime: Half Load (minutes) |
10 |
11 |
SURGE PROTECTION AND FILTERING |
Surge Energy Rating |
1000 J |
Surge Current Capability |
6,500 Amps total (one time 8 to 20us waveform) |
Surge Response Time |
0 ns (instantaneous) normal mode; <5 ns common mode |
Surge voltage let-through (as a percentage of an applied ANSI C62.41 Cat. A ±2 kV) |
<5% |
Noise Filter |
>45db normal and common mode EMI/RFI suppression |
Audible Noise at 1 m (3 ft.) |
<45 dBA |
ENVIRONMENTAL |
Operating Temperature |
0 to 40°C (+32 to +104°F) |
Operating Elevation |
0 to 3000m (0 to +10,000 ft) |
Operating/Storage Humidity |
0 to 95% non-condensing |
Storage Temperature |
-15 to +45°C (+5 to +113°F) |
Storage Elevation |
0 to 15,000m (0 to +50,000 ft) |
PHYSICAL |
Size - Net
L X W X H |
12.8 x 5.7 x 4.1"
324 x 145 x 103 mm |
12.8 x 7.8 x 4.1"
324 x 198 x 103 mm |
Weight - Net |
7.3 lbs
3.3 Kgs |
9.9 lbs
4.5 Kgs |
Size - Shipping
L X W X H |
14.9 x 5.8 x 9.0"
378 x 147 x 227 mm |
15.2 x 5.8 x 10.9"
386 x 147 x 276 mm |
Weight - Shipping |
8.4 lbs
3.8 Kgs |
10.8 lbs
4.9 Kgs |
Power Cord |
5 ft. w/5-15P |
Output Receptacles |
4 - Battery Backup & Surge
4 – Surge Only |
5 - Battery Backup & Surge
5 – Surge Only |
USB CHARGING PORTS EN600GU ONLY |
Qty / Type / Voltage / Current |
Two (2) / Type ‘A’ / 5Volts / 3Amps max total |
Specifications are subject to change without prior notice. |